<title>WFB007-S MCASE to ATO/ATC Blade Fuse Extension</title>
<link>https://us.warwickts.com:443/8896/MCASE-to-ATOATC-Blade-Fuse-Extension</link>
<enclosure url="https://us.warwickts.com:443/cache/img/261/product|8896&sz0x&cp&tn&ql&fm&bo&bc&sg59bf4cc976&ft1773048888&WFB-007-S.JPG" length="1" type="image/jpg" />
<description><![CDATA[WFB007-S Custom MCASE to ATC/ATO Blade Fuse Breakout Extension Lead for Automotive Diagnostics
The WFB007-S MCASE to ATC/ATO Blade Fuse Breakout extension lead allows you to measure the current flowing through a standard MCASE cartridge fused circuit and conduct a voltage drop test across the blade fuse enabling the identification of faulty circuits or abnormal current drain.&nbsp;&nbsp;Using the breakout extension lead also provides a&nbsp;convenient point to connect a suitable Current (Amp) Clamp to measure the amount of current flowing.&nbsp; The use of the ATC/ATO fuse also minimises the cost of fuse replacement should the fuse blow whilst conducting tests.
Max current: 30A
The fuse extension lead is simple, easy to use and will save you valuable time during your vehicle diagnostics. Just follow this guide:

Remove the fuse from the circuit you wish to test from the fuse box.
Replace it with a fuse extension lead and then insert the same value ATC/ATO fuse into the socket on the extension lead.
The current flow can then be measured by connecting your current clamp over the extension lead cable and connecting it to a multimeter or a handheld or PC based oscilloscopes from; PicoScope, Hantek, Uni-T, TiePie, CarScope, Autel MaxiScope, Sealey, Bosch, Snap-On, Fluke.

Recommended current clamps are:

CA-60&nbsp;
CA-600

Note that this product is made to order.]]></description>
<g:image_link><![CDATA[https://us.warwickts.com:443/cache/img/261/product|8896&sz0x&cp&tn&ql&fm&bo&bc&sg59bf4cc976&ft1773048888&WFB-007-S.JPG]]></g:image_link>
<g:price>20.800</g:price>
<g:product_type>Fuse Extension Breakouts</g:product_type>
<g:id>221221</g:id>
<g:brand>Warwick Test Supplies</g:brand>
</item>
<item>
<title>WFB008-S MCASE (Slotted) to ATO/ATC Blade Fuse Extension</title>
<link>https://us.warwickts.com:443/8662/MCASE-Slotted-to-ATOATC-Blade-Fuse-Extension</link>
<enclosure url="https://us.warwickts.com:443/cache/img/261/product|8662&sz0x&cp&tn&ql&fm&bo&bc&sgbb95b6a8a4&ft1721310212&WFB-007-S-1.JPG" length="1" type="image/jpg" />
<description><![CDATA[WFB008-S Custom MCASE (Slotted) to ATC/ATO Blade Fuse Breakout Extension Lead for Automotive Diagnostics
The WFB008-S MCASE (Slotted) to ATC/ATO Blade Fuse Breakout extension lead allows you to measure the current flowing through a slotted MCASE cartridge fused circuit and conduct a voltage drop test across the blade fuse enabling the identification of faulty circuits or abnormal current drain.&nbsp;&nbsp;Using the breakout extension lead also provides a&nbsp;convenient point to connect a suitable Current (Amp) Clamp to measure the amount of current flowing.&nbsp; The use of the ATC/ATO fuse also minimises the cost of fuse replacement should the fuse blow whilst conducting tests.
Max current:&nbsp; 30A
The fuse extension lead is simple, easy to use and will save you valuable time during your vehicle diagnostics. Just follow this guide:

Remove the fuse from the circuit you wish to test from the fuse box.
Replace it with a fuse extension lead and then insert the same value ATC/ATO fuse into the socket on the extension lead.
The current flow can then be measured by connecting your current clamp over the extension lead cable and connecting it to a multimeter or a handheld or PC based oscilloscopes from; PicoScope, Hantek, Uni-T, TiePie, CarScope, Autel MaxiScope, Sealey, Bosch, Snap-On, Fluke.

Recommended current clamps are:

CA-60&nbsp;
CA-600

Note that this product is made to order.]]></description>
<g:image_link><![CDATA[https://us.warwickts.com:443/cache/img/261/product|8662&sz0x&cp&tn&ql&fm&bo&bc&sgbb95b6a8a4&ft1721310212&WFB-007-S-1.JPG]]></g:image_link>
<g:price>20.800</g:price>
<g:product_type>Fuse Extension Breakouts</g:product_type>
<g:id>207830</g:id>
<g:brand>Warwick Test Supplies</g:brand>
</item>
<item>
<title>MCASE to Blade Fuse  with Aptiv-Delphi 12015791 Fuse Tap</title>
<link>https://us.warwickts.com:443/5026/MCASE-to-Aptiv-Delphi-12075791-Blade-Fuse-Extension</link>
<enclosure url="https://us.warwickts.com:443/cache/img/261/product|5026&sz0x&cp&tn&ql&fm&bo&bc&sg2ff95feea1&ft1721397820&WFB009-K-2-2.jpg" length="1" type="image/jpg" />
<description><![CDATA[WFB009-K Custom MCASE to ATO/ATC Blade Fuse Breakout with Aptiv-Delphi 12015791 Fuse Tap
The WFB009-K MCASE to ATO/ATC blade fuse with Aptiv-Delphi 12015791 1 way connectior is ideal to be able to tap an MCASE fused circuit to power auxillery circuits.&nbsp;
It can also be used as a Fuse Breakout extension lead to allow you to measure the current flowing through a standard MCASE cartridge fused circuit and conduct a voltage drop test across the blade fuse enabling the identification of faulty circuits or abnormal current drain.&nbsp;&nbsp;Using the breakout extension lead also provides a&nbsp;convenient point to connect a suitable Current (Amp) Clamp to measure the amount of current flowing.&nbsp; The use of the ATC/ATO fuse also minimises the cost of fuse replacement should the fuse blow whilst conducting tests.
Note that this product is made to order.]]></description>
<g:image_link><![CDATA[https://us.warwickts.com:443/cache/img/261/product|5026&sz0x&cp&tn&ql&fm&bo&bc&sg2ff95feea1&ft1721397820&WFB009-K-2-2.jpg]]></g:image_link>
<g:price>22.250</g:price>
<g:product_type>Fuse Extension Breakouts</g:product_type>
<g:id>173033</g:id>
<g:brand>Warwick Test Supplies</g:brand>
</item>
<item>
<title>Maxi Fuse Breakout Extension</title>
<link>https://us.warwickts.com:443/838/Maxi-Fuse-Vehicle-Breakout-Extension</link>
<enclosure url="https://us.warwickts.com:443/cache/img/261/product|838&sz0x&cp&tn&ql&fm&bo&bc&sg4e851d5645&ft1520495220&WFB003MaxiFuseBreakoutLead.jpg" length="1" type="image/jpg" />
<description><![CDATA[WFB003 Maxi Fuse Breakout Extension Lead for Automotive Diagnostics
The WFB003 Maxi Fuse Breakout extension lead allows you to measure the current flowing through a fused circuit enabling the identification of faulty circuits or abnormal current drain.&nbsp;&nbsp;Using the breakout extension lead provides a&nbsp;convenient point to connect a suitable Current (Amp) Clamp to measure the amount of current flowing.
The fuse extension lead is simple, easy to use and will save you valuable time during your vehicle diagnostics. Just follow this guide:

Remove the fuse from the circuit you wish to test from the fuse box.
Replace it with a fuse extension lead and then insert the original fuse into the socket on the extension lead.
The current flow can then be measured by connecting your current clamp over the extension lead cable and connecting it to a multimeter or a handheld or PC based oscilloscopes from; PicoScope, Hantek, Uni-T, TiePie, CarScope, Autel MaxiScope, Sealey, Bosch, Snap-On, Fluke.

&nbsp;
Recommended current clamps are:

CA-60&nbsp;
CA-600
]]></description>
<g:image_link><![CDATA[https://us.warwickts.com:443/cache/img/261/product|838&sz0x&cp&tn&ql&fm&bo&bc&sg4e851d5645&ft1520495220&WFB003MaxiFuseBreakoutLead.jpg]]></g:image_link>
<g:price>18.250</g:price>
<g:product_type>Fuse Extension Breakouts</g:product_type>
<g:id>119598</g:id>
<g:brand>Warwick Test Supplies</g:brand>
</item>
<item>
<title>JCASE Fuse Breakout Extension</title>
<link>https://us.warwickts.com:443/839/Automotive-WFB004-JCASE-Fuse-Breakout</link>
<enclosure url="https://us.warwickts.com:443/cache/img/261/product|839&sz0x&cp&tn&ql&fm&bo&bc&sg15b555288d&ft1552390956&WFB-004JCASEFuseExtension4of4.jpg" length="1" type="image/jpg" />
<description><![CDATA[WFB004 JCASE Fuse Breakout Extension Lead for Automotive Diagnostics
The WFB004 JCASE Fuse Breakout extension lead allows you to measure the current flowing through a standard or low profile JCASE fused circuit enabling the identification of faulty circuits or abnormal current drain.&nbsp;&nbsp;Using the breakout extension lead provides a&nbsp;convenient point to connect a suitable Current (Amp) Clamp to measure the amount of current flowing.
The fuse extension lead is simple, easy to use and will save you valuable time during your vehicle diagnostics. Just follow this guide:

Remove the fuse from the circuit you wish to test from the fuse box.
Replace it with a fuse extension lead and then insert the original fuse into the socket on the extension lead.
The current flow can then be measured by connecting your current clamp over the extension lead cable and connecting it to a multimeter or a handheld or PC based oscilloscopes from; PicoScope, Hantek, Uni-T, TiePie, CarScope, Autel MaxiScope, Sealey, Bosch, Snap-On, Fluke.

Recommended current clamps are:

CA-60&nbsp;
CA-600
]]></description>
<g:image_link><![CDATA[https://us.warwickts.com:443/cache/img/261/product|839&sz0x&cp&tn&ql&fm&bo&bc&sg15b555288d&ft1552390956&WFB-004JCASEFuseExtension4of4.jpg]]></g:image_link>
<g:price>17.250</g:price>
<g:product_type>Fuse Extension Breakouts</g:product_type>
<g:id>119599</g:id>
<g:brand>Warwick Test Supplies</g:brand>
</item>
<item>
<title>JCASE to ATC/ATO Blade Fuse Breakout Extension</title>
<link>https://us.warwickts.com:443/4854/JCASE-to-ATCATO-Fuse-Breakout</link>
<enclosure url="https://us.warwickts.com:443/cache/img/261/product|4854&sz0x&cp&tn&ql&fm&bo&bc&sga8a02f1018&ft1585728072&WFB006-SJCASE-ATCExt-2.jpg" length="1" type="image/jpg" />
<description><![CDATA[WFB006-S Custom JCASE to ATC/ATO Blade Fuse Breakout Extension Lead for Automotive Diagnostics
The WFB006-S JCASE to ATC/ATO Blade Fuse Breakout extension lead allows you to measure the current flowing through a standard or low profile JCASE fused circuit and conduct a voltage drop test across the blade fuse enabling the identification of faulty circuits or abnormal current drain.&nbsp;&nbsp;Using the breakout extension lead provides a&nbsp;convenient point to connect a suitable Current (Amp) Clamp to measure the amount of current flowing.&nbsp; The use of the ATC/ATO fuse also minimises the cost of fuse replacement should the fuse blow whilst conducting tests.
The fuse extension lead is simple, easy to use and will save you valuable time during your vehicle diagnostics. Just follow this guide:

Remove the fuse from the circuit you wish to test from the fuse box.&nbsp;
Replace it with a fuse extension lead and then insert the same value ATC/ATO fuse into the socket on the extension lead.
The current flow can then be measured by connecting your current clamp over the extension lead cable and connecting it to a multimeter or a handheld or PC based oscilloscopes from; PicoScope, Hantek, Uni-T, TiePie, CarScope, Autel MaxiScope, Sealey, Bosch, Snap-On, Fluke.

Recommended current clamps are:

CA-60&nbsp;
CA-600

Note that this product is made to order.]]></description>
<g:image_link><![CDATA[https://us.warwickts.com:443/cache/img/261/product|4854&sz0x&cp&tn&ql&fm&bo&bc&sga8a02f1018&ft1585728072&WFB006-SJCASE-ATCExt-2.jpg]]></g:image_link>
<g:price>17.350</g:price>
<g:product_type>Fuse Extension Breakouts</g:product_type>